That is correct. There is high voltage kickback.
A zenner diode across the sensor to "clamp the voltage" to a constant level will protect against the spikes.
The zenner value needs to match the voltage of the power supply.
For Example, 6 Volts = 6 V Zenner. 12 Volts = 12 V Zenner...