Burner problem with gauge 1 loco

Home Model Engine Machinist Forum

Help Support Home Model Engine Machinist Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.

Pufango

Member
Joined
Apr 19, 2018
Messages
20
Reaction score
7
Hello my latest build gauge 1 live steam chingford express. Runs like a Swiss clock with steam from my test boiler. But can’t get the meth burner to work longer than five minutes. Tried different wicks checked the meth is full! Must say this is the first time I’ve encountered such a problem. Anyone else had problems with a lbsc burner ?
Best regards Tony
 

Attachments

  • BEA6760B-0B9C-4466-B5CD-8979A5BE929F.jpeg
    BEA6760B-0B9C-4466-B5CD-8979A5BE929F.jpeg
    225.2 KB · Views: 3
  • 1648EAFD-3BDC-48E4-9615-33369D3FCF43.jpeg
    1648EAFD-3BDC-48E4-9615-33369D3FCF43.jpeg
    234.3 KB · Views: 3
  • 556ABC0E-0AA4-4451-8D99-09EC36BD31A1.jpeg
    556ABC0E-0AA4-4451-8D99-09EC36BD31A1.jpeg
    236.3 KB · Views: 1
could you give us some details on the burner and the firebox...
are they as per the LBSC's blue prints ?
I did a similar loco years ago, very modified, with a internally fired boiler, which runs very well.
 
Hello it’s as per lbsc drawing
 

Attachments

  • 89474561-9C0C-4655-8A67-8BA19B481E05.jpeg
    89474561-9C0C-4655-8A67-8BA19B481E05.jpeg
    247.1 KB · Views: 3
  • D4B7CCEF-00C1-45DE-8882-424106A5402B.jpeg
    D4B7CCEF-00C1-45DE-8882-424106A5402B.jpeg
    262.8 KB · Views: 2
could you give us some details on the burner and the firebox...
are they as per the LBSC's blue prints ?
I did a similar loco years ago, very modified, with a internally fired boiler, which runs very well.

Hello it as per lbsc drawings.
 
Its a pity because you did a lovely loco...

with this boiler, it seems to me that the venting is too restricted for a good combustion of the meths...
I think that after building up pressure with an auxiliary draught with an electric fan, the blower must remain open,
have a look at the burner with a mirror while it is burning, if the flame turns from blue to orange upon switching off the electric blower, "natural" draught by the exhaust is not enough for a good combustion.
it would be necessary at least to modify the exit of the burnt gases with a cone to increase the venturi effect in the exhaust.
chfrd_exp_all_VF9M.png
 
Thanks for the information. The problem is the duration of the meth burner. Me thinks it maby because I used quite a heavy gauge of material. Once the burner is getting hot it’s evaporating the meths ! Will make another one with lighter gauge materials .
 